The patient's tasks
Each manual parameter gets its own task:
Enter yesterday's steps
Enter yesterday's Intensity Minutes
Opening the task shows the manual entry screen. The patient can also enter a value from the web portal.
The task moves to completed once yesterday's value is entered.
If nothing is entered, the task disappears after the reminder's grace period.
Rules for manual values
A value always applies to the previous calendar day. The date can't be changed.
Only one value can be entered per day. Re-submitting for the same day shows an error.
Manual input isn't possible if measurements already exist for the previous day.
Values are checked and rejected with a clear, translated message when out of range:
Parameter | Accepted values |
|---|---|
Steps | 0 – 100,000 |
Intensity Minutes | 0 – 2,880 |
💡 Intensity minutes are different from clock minutes. A minute can be counted twice if the patient's heart rate is over the vigorous threshold, which is why the limit is higher than the 1,440 minutes in a day.